B Science H2O2
Hydrogen Peroxide Plasma Sterilizer
Automatic Detects Moist Load, Dries and Continues Sterilization
Real Made HRF COLD PLASMA Technology in Sterilization Chamber
BSCIENCE® Hydrogen Peroxide H2O2 Plasma Sterilizer, Automatically Detects Moist Load, Dries and Continues Sterilization.
High Technological Feature: Do Not Fall In The "Moist Load", "Moisture Detected" Trap!
Your Sterilization Will Never Be Interrupted
RELIABLE and ECOLOGIC ERA in STERILIZATION ...
BSCIENCE® Hydrogen Peroxide Sterilization Device; All kinds of plastic, polymer, inorganic, electromechanical tools and surgical instruments, etc., which can be re-used, all kinds of heat and moisture sensitive medical materials that sterilize the new generation of ecological hydrogen peroxide plasma sterilization device.
BSCIENCE® Hydrogen Peroxide (H2O2) Plasma Sterilization Device is a low-temperature, non-moisture sterilizing device that does not cause toxic wastes. It is used in the sterilization of all kinds of medical materials and medical instruments such as metal and non-metal, inorganic, polymer, etc...
BSCIENCE® Hydrogen Peroxide Gas Plasma Technology Benefits

- User and environment friendly.
- Extends the life of medical devices and instruments.
- Cost effective.
- Increases efficiency.
- In Central Sterile Supply Department (C.S.S.D) shortens the processing time.
- It is ecological.
- 37 - 55 °C operating range
- Tyvek® package compatible.
- Does not leave toxic waste.
- No need any ventilation lines.
- User and environment friendly. 10-6 (Sterility Assurance Level) Sterilization Safety Level.
- Works with 58% / %60 H2O2 cartridge.
- Sterilization is not addicted to the company and brand in the Packaging Consumables.
BSCIENCE® H2O2 Device Automatically Detects The Moist Load, Dries And Continues The Sterilization Process.
It has an HRF Plasma system that enables the conversion of Hydrogen Peroxide used in sterilization to water and oxygen.
Therefore, this system does not have harmful waste. No installation required, only electrical connection.The sterilization temperature can be set at 37 – 55 and optionally at intermediate values. It does not cause damage to plastic and electronic equipment due to low-temperature sterilization, instruments such as camera head, fiber optic cable, rigid and flexible endoscopes are safely sterilized.
It is recommended to use in the sterilization of very complex lumen materials.

BSCIENCE® H2O2 Plasma Sterilization Process
- Preparation (vacuum test, conditioning, etc.)
- Sterilization (H2O2 injection, sterilization, diffusion, plasma, etc.)
- Ventilation (Air Washing)
- All phases start and end automatically without the need for user intervention. As long as H2O2 is in the chamber, the door of the sterilization device is not opened for safety reasons without air washing.
BSCIENCE® Hydrogen Peroxide Sterilization Device Performance Chart and Validation



BSCIENCE® Lumen Sterilization (PCD)
Hydrogen Peroxide Plasma Sterilization Device; performs sterilization of conventional type disposable materials, medical products and other similar materials except endoscopes, devices, instruments. In the sterilization of H2O2 plasma, there is no need for any apparatus for the sterilization of non-complex lumens.
| Endoscopes | |
|---|---|
| Rigid Endoscopes | Flexible Endoscopes |
| Arthroscope Laryngoscope Laparoscopes Trocar Cannula Trocar Case Resectoscope etc. |
Bronchoscope Ureteroscope Hysteroscope Cystoscope Choledoscope etc.. |
| Device & Tool | |
| Defibrillator Pedals Doppler ElectroKoter Products Endoscopic Products Implants Esophageal Dilators Kri-Probe Head Pressure Transducer Cables etc.. |
Surgical Power Equipment Fiber Optic Cables Fiber Accessories Drilling & Cutting Tools Laser Hand Products Ophthalmic Lenses Radiation Therapy Instruments Ultrasound Probes Video Camera and Connection Apparatus etc.. |



BSCIENCE® Hydrogen Peroxide Sterilization Device Security Features:
- Emergency stop button,
- Audible and visual warning system showing error and error codes that may occur during sterilization stages,
- By showing the stages of sterilization; heat, pressure etc. continuously control the values and plan to work according to these values
- PLC and Microprocessor control
- To be able to do the necessary cycle system and necessary arrangements automatically with microprocessor and PLC system,
- Observation with chemical and biological indicators,
- In case of failure to reach the sterilization values, warn the user by cancelling the cycle for safety reasons,
- In case of power failure; continue the process according to the sterilization phase or terminate the program and warn the user about the absence of sterilization in writing and visually
- Overload and over-wet warning
Sterilization Device Model and Technical Specifications
| Model | BS75 | BS125 |
|---|---|---|
| TYPE | BSCIENCE ® HYDROGEN PEROXIDE | BSCIENCE ® HYDROGEN PEROXIDE |
| SCREEN | Touch Screen 7" / 10" | Touch Screen 7" / 10" |
| EXTERIOR DIMENSIONS (W-D-H) (mm) | 730 x 955 x 1860 | 730 x 955 x 1860 |
| CHAMBER INTERIOR DIMENSIONS (W-D-H) (mm) | 440 x 370 x 700 | 440 x 500 x 700 |
| CHAMBER VOLUME (Lt) | 113 | 154 |
| CHAMBER EFFECTIVE VOLUME (Lt) | 92 | 134 |
| CARTRIDGE H2O2 SOLUTION AMOUNT | 150 cc | 150 cc |
| MAXIMUM POWER (Watt) | 3200 W | 3200 W |
| WORKING VOLTAGE | 220 /230 VAC, 50/60 Hz | 220 /230 VAC, 50/60 Hz |
| EXTERIOR CHASSIS MATERIALS | STAINLESS STEEL 304 | STAINLESS STEEL 304 |
| CHAMBER MATERIAL | STAINLESS STEEL 316 | STAINLESS STEEL 316 |
| KILOGRAM | 390 | 420 |
Sterile H2O2 Agent Feature Used In Hydrogen Peroxide Sterilization Device
| H2O2 Concentration | Min %45 H2O2 Concentration and above Concentration sterilization efficiency |
| H2O2 Cartridge Feature | 45% - ... - 60% H2O2 / 100 cc - 150 cc / Safety vent |
| Cartridge Cycle Quantity | 5 cycles, 7 cycles, 10 cycles, 15 cycle cartridge/cassette types are available |
| Cartridge Shelf Life | 6/12 months from the production date at a temperature of 15-25 ˚C. |
| Waste H2O2 Drainage Feature | Yes (1 Lt disposable) |
Packaging Products Used in Hydrogen Peroxide Sterilization Device
| Compatible Packaging Materials | Tyvek® Sterilization Roller, Wrap Papers, Various Surgical Container Systems |
| Unsuitable Materials | Textile, Cellulose, Liquids |
| Indicators | Chemical and Biological Indicators |
MAINTENANCE
| Vacuum Pump and Maintenance Periods | 6 Months (300 cycles) and 1 year (600 cycles) vacuum pump oil change is also performed with the device maintenance. |
| Other Technical Specifications | The device is a mobile block type and has easy transportation and installation feature with 4 wheels, 2 of which are locked under the cabin. Needs an external power outlet. No need additional waste disposal system. |
BSCIENCE ® Hydrogen Peroxide Installation Requirement
Carry the device with the help of a pallet truck. With the help of the wheels of the device, take it from the downloaded place to the place where it will be installed. Have the device installed by our Technical Service. After the installation, the personnel who will use the device are trained and the device is explained.
For Installation;
- 220 V AC grounded socket is required.
- The environment where the device will be installed should have ventilation. Ambient temperature should not exceed the range of +15 to +35 °C.
- There should be a distance of at least 60 cm from the back and sides of the device.
'da Mevcuttur.